Magnetrol 2xx Specifications Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16
46-648 Jupiter Magnetostrictive Transmitters
1.6.4.3 Measurement Type: Interface & Level (cont.)
Display Action Comment
24
New Pass
Xxx
Enter new password Use up and down keys to select desired value (0–255)
25
Language
(select)
Select from English or
Spanish
Changes display language
26
Jupiter HT
Ver 3.0A
Display only Product software version
27
DispFact
(select)
Select Yes to display factory
parameter menus
28
History
(current status)
Enter to view history of
exceptions
Diagnostic Display
29
Run Time
Display only Elapsed time since power on; reset to zero with History Reset
30
History
Reset
Press Enter and select yes to
clear history
31
Conv Fct
xxxxxx
Factory parameter Do not adjust
32
Scl Ofst
Factory parameter Do not adjust
33
F1Thresh
Factory parameter Do not adjust
34
F1 Polar
Factory parameter Do not adjust
35
F2Thresh
Factory parameter Do not adjust
36
F2 Polar
Factory parameter Do not adjust
37
Senstvty
Factory parameter Do not adjust
38
Drv Ampl
Factory parameter Do not adjust
39
Min Sep
Factory parameter Do not adjust
40
ElecTemp
xxx C
Diagnostic Display Present temperature in electronics compartment (degrees C)
41
Max Temp
xxx c
Diagnostic Display Maximum electronics temperature recorded (degrees C)
42
Min Temp
xxx C
Diagnostic Display Minimum electronics temperature recorded (degrees C)
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 39 40